SIMATIC RF650R/RF680R/RF685R
Configuration Manual, 10/2015, C79000-G8976-C386-03
Error description
The selected frequency is not enabled.
The carrier signal is not activated.
There is more than one transponder is in the transmission window.
General radio protocol error
Error in power supply
The power supply is very close to the low limit.
Antenna error
The antenna or the antenna cable is defective.
Error in the connection to the reader; the reader is not answering (in PROFIBUS opera-
tion).
The cable between the communications module and reader is wired incorrectly or
there is a cable break
The 24 V supply voltage is not connected or is turned off or has failed briefly
Automatic fuse on the communications module has blown
Hardware defect
Another reader is in the vicinity and is active
Execute "init_run" after correcting the error
The buffer on the communications module or reader is not adequate to store the command
temporarily.
The buffer on the communications module or reader is not adequate to store the data tem-
porarily.
The command is not permitted in this status or is not supported.
Possible cause:
"INIT" was chained.
Startup message from reader/communications module
The reader or communications module was off and has not yet received a "Reset_Reader"
("WRITE-CONFIG") command.
Execute "INIT"
The same physical address in the "IID_HW_CONNECT" parameter is being used more
than once. Check your "IID_HW_CONNECT" parameter settings.
Check connection to the reader
The baud rate was switched over but power has not yet been cycled
The specified tag field of the transponder is unknown.
General error
No or bad configuration data/parameters were transferred.
Possible cause:
You are accessing an unconfigured read point.
Service and maintenance
9.2 Error messages
235