Configuring with the WBM
6.3 The menu items of the WBM
By clicking the
inventories via the SIMATIC controller or the XML interface, reads are performed cyclically
on the selected antenna and the measured values obtained are displayed. Any existing
measured values from a previous measurement are deleted. By clicking the
measurement is stopped. Clicking the
values. With the
measurement continues.
Trigger
Note
Do not use triggers during operation
We recommend that you do not use the trigger ( / ) during operation since this can disturb
operation (S7/XML application).
With the "Single" ( ) and "Start" ( ) buttons, you can trigger the selected read point and
take inventories. You require these functions to be able to run diagnostics without runtime
operation.
● Single ( )
A single trigger is fired. The read point performs precisely the number of reads entered in
"Trigger action" in the "Settings - Read point" menu item.
● Start ( / )
With
stopped.
Transponder list
After you have started the measurement, all the transponders identified by the reader are
listed in the table. Select the "EPC-ID in ASCII format" check box to display the EPC-IDs of
the transponders in ASCII code.
The output boxes:
● Transponders in list
Number of identified transponders (max. 500).
● Valid transponders
Number of identified transponders recognized by the reader as being valid since the start
of the recording and that were possibly further processed.
● Transponders in the field
Number of transponders located in the antenna field of the reader or the antenna during
the last inventory.
78
button, a new measurement is started. If you have programmed
button, you can halt the display of the RSSI graph while the
, the read point is instructed to read continuously. With
button deletes the currently displayed measured
SIMATIC RF650R/RF680R/RF685R
Configuration Manual, 10/2015, C79000-G8976-C386-03
button, the
, the read operations are

Hide quick links: