Siemens SIMATIC RF650R Configuration Manual page 210

Simatic ident
Hide thumbs Also See for SIMATIC RF650R:
Table of Contents

Advertisement

XML interface
8.3 XML commands
Parameter
value_success
value_utcTime
value_
antennaName
value_rSSI
value_channel
value_power
value_polarization
value_
commandRetry
210
Type
Values
Fixed values
True
False
Time
--
Fixed values
Antenna01
Antenna02
Antenna03
Antenna04
Decimal value
0...255
0...9
Decimal value
1...50
0...9
Decimal value
0, 5.00...33.00
0...9
Fixed values
Default
Circular
Linear_vertical
Linear_horizontal
All
Decimal value
0...65535
0...9
Description
Flag to indicate whether or not the
command was successful for this tran-
sponder.
True: Command successful
False: Command unsuccessful
Optional
UTC time stamp (Universal Time Co-
ordinated) in ISO 8601 format:
yyyy-MM-ddTHH:mm:ss.fffzzz
e.g.: 2009-12-24T18:34:56.929+00:00.
Optional
Name of the antenna
Optional
RSSI value
Optional
Channel number on which the tran-
sponder was detected.
Optional
Used radiated power of the antenna in
[dB]
Increment: 0.25 dB
Optional
Polarization of the antenna
Currently, this parameter can only be
set for the internal antenna of the
RF685R.
Optional
Number of times the reader repeated
commands attempting to obtain correct
data.
"0" corresponds to no attempt.
The maximum number of attempts is
set using the WBM.
SIMATIC RF650R/RF680R/RF685R