In the "Settings - Tag fields" menu item, you can create and edit tag fields. Tag fields are
logical memory areas of a transponder that have symbolic names. Memory areas are
defined by a logical name, the memory bank, a memory address and the length. If a tag field
is created and assigned to a read point, the data of every reliably identified transponder is
read out automatically. This data is then signaled with each "observed" "TagEventReport"
via the XML interface to the user application.
This page is divided into 3 areas:
● Tag fields
● Tag field properties
● Transponder memory configuration
Figure 6-8
Tag fields
The "Tag fields" area contains a list of all tag fields that already exist. To edit a tag field,
select the required field in the list. The selected tag field is highlighted in color. Click the
"Insert" button to create a new tag field. Click the "Delete" button to delete the selected tag
field.