Commands - Siemens SIMATIC RF650R Configuration Manual

Simatic ident
Hide thumbs Also See for SIMATIC RF650R:
Table of Contents

Advertisement

Interface to the SIMATIC controller
7.7 Programming the Ident profile
7.7.4

Commands

Table 7- 21
PHYSICAL-READ
CMD
OFFSET
LEN_
BUFFER
DATA
0x70
Offset in
Length
the
of re-
"RXREF"
ceived
receive
data
buffer
Table 7- 22
PHYSICAL-WRITE
CMD
OFFSET
LEN_
BUFFER
DATA
0x71
Offset in
Length
the
of the
"TXREF"
data to
send
be writ-
buffer
ten
Table 7- 23
READER-STATUS
CMD
OFFSETBUFFER
0x74
Offset in the "RXREF"
receive buffer
126
ADR_TAG
CHAINED EPCID_
Address on
True =
the tran-
chained
sponder
False =
not
chained
ADR_TAG
CHAINED EPCID_
Address on
True =
the tran-
chained
sponder
False =
not
chained
ATTRIBUTES
Identifier of the status
mode "0x89"
LEN_ID
UID
Buffer for up to
Length of
62 bytes EPC-
the EPC-
ID
ID (2-62
bytes)
2 - 62-byte
EPC-ID is en-
0x00 ≙
tered at the
unspeci-
start of the
fied single
buffer (length is
tag ac-
set by
cess
"LEN_ID")
Default value:
0x00 ≙ unspeci-
fied single tag
access
LEN_ID
UID
Buffer for up to
Length of
62 bytes EPC-
the EPC-
ID
ID (2-62
bytes)
2 - 62-byte
EPC-ID is en-
0x00 ≙
tered at the
unspeci-
start of the
fied sin-
buffer (length is
gle tag
set by
access
"LEN_ID")
Default value:
0x00 ≙ unspeci-
fied single tag
access
CHAINED
True = chained
False = not chained
Configuration Manual, 10/2015, C79000-G8976-C386-03
MEM_
PSWD
BANK
Memory
Pass-
bank
word
0x00 ≙
0x00 ≙
no pass-
reserved
pass-
0x01 ≙
word
EPC
0x02 ≙
TID
0x03 ≙
USER
MEM_
PSWD
BANK
Memory bank
Pass-
word
0x00 ≙
0x00 ≙
reserved
no pass-
0x01 ≙
pass-
EPC
word
0x02 ≙
TID
0x03 ≙
USER
IDENT_
DATA
Received status data
You will find the data structure of
the status mode in the section
"Reader_Status (Page 120)".
SIMATIC RF650R/RF680R/RF685R
IDENT_
DATA
Read
data
IDENT_
DATA
Data to
be written

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simatic rf680rSimatic rf685r

Table of Contents