Getobservedtagids - Siemens SIMATIC RF650R Configuration Manual

Simatic ident
Hide thumbs Also See for SIMATIC RF650R:
Table of Contents

Advertisement

Parameter
value_rSSI
value_channel
value_power
value_polarization
value_inventoried
Value_
filterDataAvailable
8.3.3.6

getObservedTagIDs

With this command, the selected read point takes an inventory and returns all identified
transponders in the reply frame.
In contrast to the "readTagIDs" command, the smoothing algorithm of the selected read point
is also affected here. The read point must therefore take enough inventories until a
transponder adopts the "Observed" status. This can be achieved by selecting the suitable
parameter values or by triggering/starting the read point in good time before the command.
If no transponder was identified with the "Observed" status, a positive reply without
transponder data is returned.
SIMATIC RF650R/RF680R/RF685R
Configuration Manual, 10/2015, C79000-G8976-C386-03
Type
Values
Decimal value
0...255
0...9
Decimal value
1...50
0...9
Decimal value
0, 5.00...33.00
0...9
Fixed values
Default
Circular
Linear_vertical
Linear_horizontal
All
Decimal value
0...65535
0...9
Fixed values
True
False
XML interface
8.3 XML commands
Description
Optional
RSSI value
Optional
Channel number on which the tran-
sponder was detected.
Optional
Used radiated power of the antenna in
[dB]
Increment: 0.25 dB
Optional
Polarization of the antenna
Currently, this parameter can only be
set for the internal antenna of the
RF685R.
Optional
Indicates how often the transponder
was identified via the air interface in
this command.
Optional
Indicates whether or not a filter criteri-
on was received.
True:
All the data was read or there was
no filter set.
False:
Data could not be read.
177

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simatic rf680rSimatic rf685r

Table of Contents