MP
Function and input
MP1087.x
Maximum permissible axis-specific jerk for "Manual mode"
Input:
MP1088.x
Axis-specific jerk limiting for unfiltered positioning movements
Input:
MP1089.x
Max. permissible axis-specific jerk for "Pass Over Reference Point" mode
Input:
MP1090
Maximum permissible jerk on the tool path
Input:
0.0 to 9999.9 [m/s³ or °/s³]
MP1090.0
For movements not at rapid traverse or feed rate < MP1092
MP1090.1
For movements at rapid traverse or feed rate > MP1092
MP1092
Feed rate threshold for MP1085.x and MP1086.x
Input:
0: Not active
MP1094
HSC filters
Input:
0.1 to 166.0: Cutoff frequency for HSC filter
MP1095
Nominal position value filter
Input:
1: Double filter
MP1095.0
In the Program Run Full Sequence, Program Run Single Block, and Positioning With
Manual Data Input operating modes
MP1095.1
In the Manual, Handwheel, Jog Increment and Pass Over Reference Point operating
modes
MP1096
Tolerance for contour transitions at corners
Input:
0.001 to 3.000 [mm]
MP1096.0
With machining feed rate
MP1096.1
With rapid traverse
MP1097.x
Maximum permissible axis-specific jerk (single/HSC filter)
Input:
July 2010
0.1 to 1000.0 [m/s³ or 1000 °/s³]
0.1 to 9999.9 [m/s³]
0.1 to 1000.0 [m/s³ or 1000 °/s³]
0: Not active
1 to 300 000 [mm/min] (previous behavior)
0: HSC filter inactive
0: Single filter
0: No nominal position value filter
0.1 to 1000.0 [m/s³ or 1000 °/s³]
SW version
and
behavior
PLC
RUN
340 490-05
PLC
RUN
PLC
RUN
340 490-04
PLC
RUN
340 490-03
As of
340 490-01,
340 492-01
only via
MPMODE =
340422 in
OEM.SYS
PLC
RUN
As of
340 490-01,
340 492-01
only via
MPMODE =
340422 in
OEM.SYS
PLC
RUN
As of
340 490-01,
340 492-01
only via
MPMODE =
340422 in
OEM.SYS
PLC
RUN
As of
340 490-01,
340 492-01
only via
MPMODE =
340422 in
OEM.SYS