18.2.6 Possibilities with the integrated oscilloscope

As of NC software version 34049x-04 in combination with the CC 424 (B), the incremental
signals (A, B) can be recorded with the integrated oscilloscope.
Activation and operation --> See "Integrated Oscilloscope" on page 10 – 99.
Example for an oscilloscope recording of motor encoder signals:
July 2010
Note
Reference signals and EnDat signals cannot be displayed!
A phase angle measuring unit should be used for an accurate tracing of the signals
(e.g., PWM 9)!
Make the following settings:
Move the X-axis at very low speed in the manual mode.
Start the oscilloscope recording.
Stop recording.
Adapt the signals under consideration of the zero line.
Adapt the time axis for a more detailed representation.