D-sub connector, 26-pin
X147:
PLC Expansion
for PL 510
on the MC 420
MC 420
Male
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
Housing
27 – 484
Note
The interface complies with the requirements of EN 61800-5-1 for "protective extra-low
voltage" (PELV).
DANGER
Only units that comply with the requirements of EN 61800-5-1 for "protective extra-low
voltage" (PELV) may be connected.
Connecting cable ID 371 046-xx
Pin layout
Female
0 V
1
0 V
2
0 V
3
Do not assign 4
Address 6
5
INTERRUPT
6
RESET
7
WRITE
8
EXTERN
WRITE
9
EXTERN
Address 5
10
Address 3
11
Address 1
12
Do not assign 13
+5 V (output)
14
+5 V
15
(feedback)
PCB identifier
16
2
PCB identifier
17
1
Address 7
18
Serial IN 1
19
EM. STOP
20
Serial OUT
21
Serial OUT
22
Address 4
23
Address 2
24
Address 0
25
26
External
Housing
shield
Black
Violet
Yellow
Blue
Red
Gray
Pink
Green
White
Brown
White/Blue
Brown/Blue
White/Pink
Pink/Brown
Brown/Green
WH/GY
Gray/Brown
White/Yellow
Yellow/Brown
White/Green
GY/PK
Red/Blue
External shield
HEIDENHAIN Service Manual iTNC 530
First PL 510
Male
X1
Pin layout
female
1
1
0 V
2
2
0 V
3
3
0 V
4
4
Do not assign
5
5
Address 6
6
6
INTERRUPT
7
7
RESET
8
8
WRITE
EXTERN
9
9
WRITE
EXTERN
10
10
Address 5
11
11
Address 3
12
12
Address 1
13
13
Do not assign
14
14
15
15
16
16
PCB identifier
2
17
17
PCB identifier
1
18
18
Address 7
19
19
Serial IN
20
20
EM. STOP
21
21
Serial OUT
22
22
Serial OUT
23
23
Address 4
24
24
Address 2
25
25
Address 0
26
26
Housing
Housing
External
shield

Hide quick links: