Operand
Description
M
4053
Probing process has been completed or canceled
M
4054
Battery voltage too low (battery warning at touch probe connection);
evaluated only during the probing process
M
4055
Enable the probing process
M
4056
NC stop in all operating modes if stylus is deflected
M
4057
Touch probe cycles active (FN17: ID990 NR2)
M
4060
Cycle for tool measurement started
M
4061
0: Measure the tool
1: Check the tool
M
4062
0: Wear tolerance not exceeded
1: Wear tolerance exceeded
M
4063
0: Breakage tolerance not exceeded
1: Breakage tolerance exceeded
M
4065
Workpiece dimensions are OK
M
4066
Workpiece must be reworked
M
4067
Workpiece is scrap
Strobe signals from the PLC to the NC
Operand
Description
M
4070
Strobe signal for gear code
M
4071
Strobe signal for S code
M
4072
Strobe signal for M functions
M
4073
Strobe signal T code (P code) with TOOL CALL
M
4074
Strobe signal T code (P code) with TOOL DEF
M
4075
Transfer active with FN19
Acknowledgment of NC strobe signals
Operand
Description
M
4090
Acknowledgment of "gear change completed"
M
4091
Acknowledgment of S code
M
4092
Acknowledgment of M function
M
4093
Acknowledgment of T code (P code) with TOOL CALL
M
4094
Acknowledgment of T code (P code) with TOOL DEF
M
4095
Acknowledgment of transfer with FN19
Strobe signals from the PLC to the NC
Operand
Description
M
4120 -
PLC positioning axis 1 to 9 active
4128
M
4130
Activation of spindle orientation, or spindle orientation has been
started with Module 9171
M
4131
Activation of Q-parameter transfer to the NC; data from D258, Q
number from W516
M
4132
Activate datum shift from D528 to D544, or call module 9230
M
4133
Starting and stopping the free rotation function
M
4134
Activation of a gear range and speed through the PLC
M
4135
Strobe marker for selecting the traverse range
July 2010
Set
Reset As of SW vers.
NC
NC
NC
NC
Not supported
as of
340 422-03,
340 480-03
NC
PLC
PLC
PLC
NC
NC
340 422-09,
340 480-09
NC
NC
NC
NC
NC
NC/
PLC
NC
NC/
PLC
NC
PLC
NC
PLC
NC
PLC
Set
Reset As of SW vers.
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
Set
Reset As of SW vers.
PLC
PLC
PLC
PLC
PLC
PLC
PLC
PLC
PLC
PLC
PLC
PLC
Set
Reset As of SW vers.
NC/
NC/
PLC
PLC
NC/
NC
PLC
PLC
NC
PLC
NC
PLC
NC
PLC
NC
PLC
NC