Checking The Drive Enabling For The Axis Groups Via Connector X150 And X151 (If Wired) - HEIDENHAIN iTNC 530 Service Manual

Hide thumbs Also See for iTNC 530:
Table of Contents

Advertisement

16.2.3 Checking the drive enabling for the axis groups via connector X150 and X151 (if wired)

The axis groups for the drive enabling via X150 (main DCB) and X151 (auxiliary DCB) are defined
in MP2040.
Call via the soft keys DIAGNOSIS --> DRIVE DIAGNOSIS --> DSP.
Page from the
See "Integrated Diagnostic Functions and DriveDiag" on page 9 – 89.
integrated drive
diagnosis
Figure: The axes are displayed next to each other.
Call via the soft keys DIAGNOSIS --> DRIVE DIAGNOSIS --> DRIVEDIAG.
Page from
See "Integrated Diagnostic Functions and DriveDiag" on page 9 – 89.
DriveDiag
Figure: Here each axis is shown on an individual page.
16 – 242
Check whether 24V are available for the axis group to be traversed.
Check according to the integrated drive diagnosis or DriveDiag whether the corresponding
axis groups are released:
Note
If no axis groups are defined in MP 2040, the default setting of the drive release is active
(via X150 / X151).
HEIDENHAIN Service Manual iTNC 530

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents