2.4 Installation Direction and Space

Notes:
Incorrect installation may result in a drive malfunction or premature failure of the drive
and or motor.
The ASDA-B2 servo drive should be mounted perpendicular to the wall or in the
control panel. In order to ensure the drive is well ventilated, ensure that the all
ventilation holes are not obstructed and sufficient free space is given to the servo
drive. Do not install the drive in a horizontal position or malfunction and damage will
occur.
Do not parallel connect the servo drive, or it might burn out the soft-start resistance or
the commutator and danger will occur.
Drive Mounting
The ASDA-B2 servo drives must be back mounted vertically on a dry and solid surface
such as a NEMA enclosure. A minimum spacing of two inches must be maintained above
and below the drive for ventilation and heat dissipation. Additional space may be
necessary for wiring and cable connections. Also, as the drive conducts heat away via the
mounting, the mounting plane or surface should not conduct heat into the drive from
external sources
Motor Mounting
The ECMA servo motors should be mounted firmly to a dry and solid mounting surface to
ensure maximum heat transfer for maximum power output and to provide a good ground.
For the dimensions and weights specifications of servo drive or motor, please refer to
Chapter 10 - Specifications.