DURKOPP ADLER 581 Operating Instructions Manual page 169

Table of Contents

Advertisement

Troubleshooting
Error
Meaning
.. .. 22
Magnet wheel search
timeout
.. .. 30
Stepper motor not
responding
.. .. 41
Stepper motor not
responding
.. .. 52
Stepper motor
overcurrent
.. .. 53
Stepper motor
overvoltage
.. .. 55
Stepper motor
overload
.. .. 56
Stepper motor
overtemperature
.. .. 62
Stepper motor IDMA
auto-increment
3100
Machine: Voltage fault • Temporary line voltage
3103
3221
Machine: Thread
tension regulation
3222
Operating Instructions 581 - 01.0 - 05/2016
Possible cause
• Stepper motor card
defective
• Stepper motor defective
• Control defective
• Line voltage too high
• Stepper motor not moving
freely or blocked
• Stepper motor defective
• Control defective
• Stepper motor not moving
freely
• Stepper motor defective
• Control defective
• Disturbance
interruption
• Internal error
Remedial action
• Check connection cables
• Check stepper motor for stiff
movement
• Perform software update
• Replace the control
• Perform software update
• Replace stepper motor card
• Replace the stepper motor
• Replace the control
• Check the line voltage
• Eliminate sluggishness/
blockage
• Replace the stepper motor
• Replace the control
• Eliminate sluggishness
• Replace the stepper motor
• Replace the control
• Switch the machine off and
on again
• Check line voltage and
stabilize, if required
• Switch the machine off and
on again
• Perform software update
• Contact Customer Service
167

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents