DURKOPP ADLER 581 Operating Instructions Manual page 166

Table of Contents

Advertisement

Error
Meaning
1053
Line voltage too high
1054
Internal short circuit
1055
Sewing motor overload • Sewing motor is sluggish or
1056
Sewing motor
overtemperature
1058
Sewing motor speed
is greater than the
setpoint
1060
PowerParts
1062
Sewing motor IDMA
auto-increment
1120
Software error
1203
Sewing motor:
Position not reached
1302
Sewing motor current
feed fault
1330
Sewing motor not
responding
164
Possible cause
• Line voltage too high
is blocked
• Sewing motor defective
• Control defective
• Sewing motor not moving
freely
• Sewing motor defective
• Control defective
• Reference switch defective
• Sewing motor defective
• Disturbance
• Parameter not initialized
• Sewing motor blocked
• Encoder cable not
connected or defective
• Encoder defective
Operating Instructions 581 - 01.0 - 05/2016
Troubleshooting
Remedial action
• Check the line voltage
• Replace the control
• Eliminate sluggishness/
blockage
• Replace the sewing motor
• Replace the control
• Eliminate sluggishness
• Replace the sewing motor
• Replace the control
• Replace reference switch
(9815 935006)
• Replace the sewing motor
• Replace the control
• Switch the machine off and
on again
• Perform software update
• Switch the machine off and
on again
• Perform software update
• Contact Customer Service
• Remove the blockage
• Check the encoder cable
and replace, if necessary
• Replace the sewing motor
• Switch the machine off and
on again
• Perform software update
• Contact Customer Service

Hide quick links: