Advertisement

Precautions for Correct Use
• When the Drive Programming program is stopped, the status of the input terminal variables is
not retained but updated according to the status of actual input terminals.
• Even when you set MI1 to MI12 (general-purpose input 1 to 12) for the Multi-function Input ter-
minals, you can select NO (NO contact) or NC (NC contact) for the Multi-function Input S1 to S7
Operation Selection (C011 to C017).
Output Terminal Variables Y(00) to Y(06)
You can use the inverter's multi-function output terminals as the output terminal variables Y(00) to Y(06)
for the Drive Programming function by setting the multi-function output terminals to the general-purpose
outputs MO1 to MO7.
You can also use the input terminal variables Y(00) to Y(06) as word-access data, which are set to the
lower byte by using the variable Yw.
Function
variable
Y(00) to Y(06)
• You can control the status of the multi-function output terminals 11 to 13 and the multi-function relay
output terminal (RY) as bit-size variables.
• By setting the Multi-function Output 11 to 13 Selection (C021 to C023) or the Multi-function Relay
Output (RY) Function Selection (C026) to 35 to 41 (MO1 to MO7: General-purpose output), you can
control the output terminals 11 to 13 or the relay output terminal (RY) as the output terminal variables
Y(00) to Y(06) of the Drive Programming. Numbers are given to the output terminal variables Y(00) to
Y(06) according to the numerical order of the set general-purpose outputs MO1 to MO7, not the ter-
minal numbers 11 to 13, RY.
Function variable
Y(00)
Y(01)
Y(02)
Y(03)
Y(04)
Y(05)
Y(06)
Function
variable
Yw
Output terminal variable
(word access)
• The output terminal variables (word access) Yw is a function to use the output terminal variables Y(00)
to Y(06) as a word-size variable.
• The output terminal variables Y(00) to Y(06) are set in the lower byte. For the upper byte and unused
output terminal variables, zero is read out. If any data is written to the upper byte, the data is ignored.
Bit
Function
Drive Programming User's Manual (I580-E2)
Description
Output terminal variable
0: OFF
(bit access)
1: ON
Setting for Multi-function Output Selection
(C021, C022, C023 and C026)
Description
7 to 15
6
5
Not used
Y(06)
Y(05)
Default
Data range
data
0
35: MO1
36: MO2
37: MO3
38: MO4
39: MO5
40: MO6
41: MO7
Default
Data range
data
0 to 255
0
4
3
Y(04)
Y(03)
9 LX inverter
Unit
Data size
R/W
bit
Unit
Data size
R/W
Unsigned
1 word
2
1
0
Y(02)
Y(01)
Y(00)
9 - 7
R
9
R