Omron 3G3MX2 Series User Manual page 139

Drive programming
Hide thumbs Also See for 3G3MX2 Series:
Table of Contents

Advertisement

6 Drive Programming Commands
Y(i)  value
Command
Outputs data to the output terminal variable in
units of bits.
Note The output terminal variable is a variable that controls the status of the inverter's output termi-
MX2:
Set the Multi-function Output P1 and P2 Selection (C021 and C022) and the Multi-function Relay Out-
put (MA, MB) Function Selection (C026) to 44 to 46 (MO1 to MO3: General-purpose output).
RX:
Set the Multi-function Output P1 to P5 Selection (C021 to C025) and the Multi-function Relay Out-
put (MA, MB) Function Selection (C026) to 44 to 49 (MO1 to MO6: General-purpose output).
<Assignment example>
Y(00)  MO1 (multi-function No. 44)
Y(01)  MO2 (multi-function No. 45)
Y(02)  MO3 (multi-function No. 46)
Y(03)  MO4 (RX only: multi-function No. 47)
Y(04)  MO5 (RX only: multi-function No. 48)
Y(05)  MO6 (RX only: multi-function No. 49)
For details, refer to 5-2 Input/Output Terminal Variables on page 5-5.
 Example
In the above example, the status of X(00) to X(02) is monitored with the parameter UMon(0) (d025), and X(02) is output to Y(00).
Block number
1
Assigns 0 to UBw.
2 to 4
Assigns the variables X(00) to X(02) to the variables UB(0) to UB(2).
5
Assigns UBw to UMon(0).
6
Assigns UB(2) to Y(00).
7
Jumps to the block 1: loop_ unconditionally.
6 - 38
Description
Flowchart method
Y(i) :
<value>
nal. The following settings are required. The numerical order of the output terminal variables
follows the numerical order of the set general-output numbers.
Flowchart
i: output terminal variable
(range 0 to 6)
Value: any variable or constant
Format
Text language method
Y(i) :  <value>
Operation
Drive Programming User's Manual (I580-E2)
Argument
Text