Function
variable
Tmon
Output Torque Monitor
(d012)
Use this function to monitor the output torque. The monitored data is equivalent to the data of the Out-
put Torque Monitor (d012). This variable is read-only.
Function
variable
Vout
Output Voltage Monitor
(d013)
Use this function to monitor the output voltage. The monitored data is equivalent to the data of the Out-
put Voltage Monitor (d013). This variable is read-only.
Function
variable
Power
Input Power Monitor
(d014)
Use this function to monitor the input power. The monitored data is equivalent to the data of the Input
Power Monitor (d014). This variable is read-only.
Function
variable
RUN-Time
Total RUN Time Monitor
(d016)
Use this function to monitor the total operation time. The monitored data is equivalent to the data of the
Total RUN Time Monitor (d016). This variable is read-only.
Function
variable
ON-Time
Total Power ON Time
Monitor (d017)
Use this function to monitor the total power ON time. The monitored data is equivalent to the data of the
Total Power ON Time Monitor (d017). This variable is read-only.
Function
variable
UMon(0) to
User Monitor 0 to 2
UMon(2)
(d025 to d027)
The Drive Programming's user monitor variables UMon(0) to UMon(2) are the signed 2-word variables.
If any data is set in the user monitor variables UMon(0) to UMon(2) in the Drive Programming program,
the data can be displayed through the inverter's user monitor parameters (d025, d026 and d027). Use
this function to externally display the calculation status of the program.
Function
variable
POS
Current Position Monitor
(d030)
Use this function to monitor the current position. The monitored data is equivalent to the data of the
Current Position Monitor (d030).
*1. The range of display shown in ( ) is for RX only.
This range of display is used when the V2 Control Mode Selection (P012) is set to 03 (HAPR: High-resolution
absolute position control mode).
Drive Programming User's Manual (I580-E2)
Description
Data range
200 to 200
Description
Data range
0 to 6,000
Description
Data range
0 to 9,999
Description
Data range
0 to 999,999
Description
Data range
0 to 999,999
Description
Data range
2,147,483,647 to
2,147,483,647
Description
Data range
268,435,455 to
268,435,455
(1,073,741,823 to
1,073,741,823)
5 Drive Programming User Variables
Default
Unit
data
%
Default
Unit
data
0.1 V
Default
Unit
data
0.1 kW
Default
Unit
data
Time
Default
Unit
data
Time
Default
Unit
data
0
Default
Unit
data
1
*1
Data size
R/W
Unsigned
R
1 word
Data size
R/W
Unsigned
R
1 word
Data size
R/W
Unsigned
R
1 word
Data size
R/W
5
Unsigned
R
2 words
Data size
R/W
Unsigned
R
2 words
Data size
R/W
Signed
R/W
2 words
Data size
R/W
Signed
R
2 words
5 - 15