 Example
In the above example, the start/end operation of the timer (0) is repeated when X(01) is not 0. If X(01)
changes to 0, the timer is stopped and X(01) is monitored.
Block number
1
Assigns 20 to U(01).
2
Jumps to the block 1: loop_ if X(01) is 0. Goes to the next step if X(01) is not 0.
3
Starts the timer (0) for the "timer set" command with the set value U(01).
4 to 9
Monitors X(01) and jumps to the block 10: LB0001_ when TD(0) is 1 and X(01) is not 0.
When X(01) changes to 0, the timer (0) stops and the program goes to the next step.
10
Jumps to the block 1: loop_ unconditionally.