Emergency Stop - ABB IRC5 Product Manual

Robot controller
Hide thumbs Also See for IRC5:
Table of Contents

Advertisement

1
2
PROCESS POWER SUPPLY
/33.2 /87.4 / 24V SYS
/33.2 /87.5 / 0V SYS
/33.2 /87.4 / 24V COOL
/33.2 /87.5 / 0V COOL
INTERNAL
FAN
-E3
M
2
1
EXTERNAL
EMERGENCY
2 2
1 1
STOP PB
EMERGENCY
STOP OUTPUT 1
EMERGENCY
STOP OUTPUT 2
OPTION:
EXTERNAL
CONNECTIONS
SEE PAGE
49
EXTERNAL
SUPPLY

EMERGENCY STOP

RELAY SIGNALS
Latest revision:
Prepared by, date:
Approved by, date:
3
4
PANEL BOARD
-A21
-X12
24V FPU POWER
24V SYS
24V PANEL
1 1
0V SYS
2 2
3 3
4 4
-X1
ES1 top
3 3
-X2
ES2 top
3 3
0V
0V
24V Panel
4 4
24V PANEL
4 4
Run CH1 top
Run CH2 top
5 5
5 5
ES1OUT:A
ES2 OUT:A
1 1
1 1
ES2 OUT:B
ES1OUT:B
2 2
2 2
Sep ES2:A
RunCh0V
Sep ES1:A
RunCh+
9 9
9 9
-ES2
-ES1
U
Sep ES1:B
10
10
Sep ES2:B
10
10
ES2 bottom
ES1 bottom
7 7
0V
7 7
24V Panel
8 8
8 8
24V PANEL
ES1:int
6 6
ES2:int
6 6
5
U
SOFT_ESO
SOFT_ESI
0V
ES1
ES2
Lab/Office:
CONTROL SYS. IRC5 M2004 DESIGN 06
EMERGENCY STOP
6
7
-X10
-209
AWG20 BU
ES FPU 1:A / /47.2 /48.2
5 5
-211
AWG20 BU
ES FPU 2:A / /47.2 /48.2
7 7
-212
AWG20 BU
ES FPU 2:B / /47.2 /48.2
8 8
-210
AWG20 BU
ES FPU 1:B / /47.2 /48.2
6 6
EMERGENCY PB
-S21.3
-X9
-237
AWG20
-238
17
17
AWG20
-233
18
18
AWG20
-234
13
13
AWG20
-231
14
14
AWG20
-232
11
11
AWG20
-235
12
12
AWG20
-236
15
15
AWG20
16
16
AWG24
-X11
1 1
24V_Sig.ref. / /50.7
2 2
WHGN
RS485+ / /50.7
3 3
BU
RS485- / /50.7
4 4
WHBU
5 5
0V_Sig.ref. / /50.7
6 6
WHBN
7 7
8 8
Status:
2008-07-17
Plant:
Location:
Approved
Sublocation:
Document no.
3HAC024480-004
8
FPU
21
22
11
12
MAIN
COMPUTER
=
CAB
+
CM
+
Rev. Ind
Page 38
Next
39
03
Total
153

Advertisement

Table of Contents
loading

Table of Contents