INSTALLATION REQUIREMENTS

Figure 5 -
Measure Heat Resistant Material for Mantel
Heat resistant material (minimum requirements) with
wooden mantel or other combustible projection:
To install the heater with a wooden mantel, shelf or other
combustible projection above, fi rst measure the heat resis-
tant material shown in Figure 6, then see TABLE B.
Table B -
Heat Resistant Material Heights and Mantel Location
Requirements for Safe
Heat Resistant
Installation with Wooden Mantel,
Material
Shelf or Other Combustible
Measurement
Projection
12" or more
Hood not required. Observe
profi les (side elevations) shown in
Figure 7
8" or less than
Install hood (CABR/CABL) and
12"
observe profi les show in Figure 6;
OR extend heat resistant material
to at least 12" and observe profi les
shown in Figure 7
Less than 8"
Extend heat resistant material to
at least 8" and install hood (CABR/
CABL) and observe profi les
shown in Figure 6; OR extend
heat resistant material to at least
12" and observe profi les shown in
Figure 7.
65D2035
8" or More of Heat
Resistant Material
Hood
Heater in
Fireplace or
Figrebox
FP2923
12"
10"
8"
6"
Heat
Resistant
2 "
Material
Heater in
Fireplace or
Firebox
FP2534
Figure 6 -
Minimum Mantel Clearance with Hood
Example: A mantel may project from the wall a maximum
of 2
1
" at a minimum of 8" above the opening
2
and a maximum of 6" at a minimum of 14
above the opening.
Heat
Resistant
Material
Figure 7 -
Minimum Mantel Clearance with No Hood
Example: The bottom of the mantel may project from the
wall a maximum of 10" at a minimum of 28"
above the opening.
PH Gas Logs
8"
14 " 18 " 22 " 26"
Hood
10" or Less
28"
12"
Min.
Heater in
Fireplace or
Firebox
FP2535
1
"
2
9