OPERATION
The Stardance is operated with the front plate in place
with the doors open or closed, and the safety barrier in
place. To open the front doors, pull forward to separate
the magnetic catch.

YOUR FIRST FIRE

Read these instructions carefully and familiarize yourself
with the burner controls shown on Page 32 (SDDVT
models) or page 35 (SDVTSC models). Locate the pilot
assembly, Figure 55. Follow the lighting instructions in this
manual exactly.
During the first fire, it is not unusual to smell some odor
associated with new logs, paint and metal being heated.
Odors should dissipate within the first eight to ten hours,
however, you can open a window to provide fresh air to
alleviate the condition.
Pilot Assembly
Figure 55 Pilot Assembly location.

PILOT AND BURNER INSPECTION

Each time you light your heater check that the pilot flame
and burner flame patterns are as shown in Figure 56. If
flame patterns are incorrect, turn the heater off. Contact
your dealer or a qualified gas technician for assistance.
Do not operate the heater until the pilot flame is correct.
Follow regular maintenance procedures as described in the
Cleaning and Maintenance section of this manual.
20306760
ST477a
Stardance
pilot location
10/4/00

FLAME CHARACTERISTICS

It is important to periodically perform a visual check of the
pilot and the burner flames. Compare them to Figure 56. If
any of the flames appear abnormal, call a service person.
SDDVT MODELS
ST476
SDVTSC MODELS
Figure 56 Correct pilot and burner flame appearance.
FLAME & TEMPERATURE ADJUSTMENT
CO105d
For SDDVT models which are equipped with HI/LO valves,
flame adjustment is accomplished by rotating the HI/LO
Pilot flame
adjustment knob located near the center of the gas control
6/07 djt
valve. (Figure 57)
Turn
counterclockwise
to increase
flame height
Figure 57 Flame adjustment knob for SIT valve.

OPERATING INSTRUCTIONS

Sensor
Thermopile
FP2453
hooded pilot flames
Turn clockwise
to decrease
flame height
FP390
FLAME ADJUSTMENT KNOB