Supplementary system components and encoder system integration
8.2 Sensor Module Cabinet-Mounted SMC10
8.2.4

Meaning of the LED

Table 8- 6
Meaning of the LED on the Sensor Module Cabinet-Mounted SMC10
LED
Color
RDY
-
Off
READY
Green
Continuous
light
Orange
Continuous
light
Red
Continuous
light
Green/
Flashing
red
light 0.5 Hz
Flashing
light 2 Hz
Green/
Flashing
orange
light
or
Red/
orange
See SINAMICS S110 List Manual for the parameters to activate component recognition via LED
1)
Cause and rectification of faults
The following documents contain information about the cause of faults and how they can be
rectified:
● SINAMICS S110, Function Manual
● SINAMICS S110, List Manual
176
Status
The electronics power supply is missing or outside the per-
missible tolerance range.
The component is ready for operation. Cyclic DRIVE-CLiQ
communication is taking place.
DRIVE-CLiQ communication is being established.
This component has at least one fault.
Note:
The LED is activated irrespective of whether the corre-
sponding messages have been reconfigured.
Firmware is being downloaded.
Firmware download is complete. The system waits for
POWER ON.
Component recognition via LED is activated
Note:
Both options depend on the LED status when component
recognition is activated.
Description, cause
.
1)
Remedy
Remove and
acknowledge the fault.
Carry out a POWER
ON.