X520 Encoder System Interface - Siemens SINAMICS S110 Manual

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

Supplementary system components and encoder system integration
8.2 Sensor Module Cabinet-Mounted SMC10
8.2.3.3

X520 encoder system interface

Table 8- 4
X520: Encoder system interface
Pin
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
Connector type:
25-pin SUB D connector
Measuring current via temperature sensor connection: 2 mA
Accuracy of temperature measurement:
1)
- KTY: ±7 °C (incl. evaluation)
- PTC: ±5 °C (incl. evaluation)
174
Signal name
Reserved, do not use
Reserved, do not use
S2
S4
Ground
S1
S3
Ground
R1
Reserved, do not use
R2
Reserved, do not use
+ Temp
1)
Reserved, do not use
Reserved, do not use
Reserved, do not use
Reserved, do not use
Reserved, do not use
Reserved, do not use
Reserved, do not use
Reserved, do not use
Reserved, do not use
Reserved, do not use
Ground
- Temp
1)
Technical data
Resolver signal A (sin+)
Inverted resolver signal A (sin-)
Ground (for internal shield)
Resolver signal B (cos+)
Inverted resolver signal B (cos-)
Ground (for internal shield)
Resolver excitation positive
Resolver excitation negative
Motor temperature sensing KTY84-1C130 (KTY+)
Temperature sensor KTY84-1C130 / PTC
Ground (for internal shield)
Motor temperature sensing KTY84-1C130 (KTY-)
Temperature sensor KTY84-1C130 / PTC
Manual, 07/2015, 6SL3097-4AC10-0BP5
SINAMICS S110

Advertisement

Table of Contents
loading