Technical Data - Siemens SINAMICS S110 Manual

Hide thumbs Also See for SINAMICS S110:
Table of Contents

Advertisement

6.1.6

Technical data

Table 6- 3
Motor reactors for Power Modules PM240-2, part 1
Article No. 6SL3202-
Inductance
Rated current
Power loss
Degree of protection
Weight
Matching Power Modules
Frame size
Unit rating of the Power Module
x = A: Power Module with integrated line filter, x = U: Power Module without integrated line filter
1)
Table 6- 4
Motor reactors for Power Modules PM240-2, part 2
Article No. 6SE6400-
Inductance
Rated current
Power loss
Degree of protection
Weight
Matching Power Modules
Frame size
Unit rating of the Power Module
x = A: Power Module with integrated line filter, x = U: Power Module without integrated line filter
1)
SINAMICS S110
Manual, 07/2015, 6SL3097-4AC10-0BP5
0AE16-1CA0
mH
2.5
A
6.1
kW
0.09
IP20
kg
3.4
Line voltage 1/3-phase 200 V AC -10 % to 240 V AC +10 %:
1)
6SL3210-
1PB13-0xL0
1PB13-8xL0
1PB15-5xL0
6SL3211-
1PB13-8xL0
Line voltage 3-phase 380 V AC -10% to 480 V AC +10%:
6SL3210-
1PE11-8xL1
1PE12-3xL1
1PE13-2xL1
1PE14-3xL1
1PE16-1xL1
FSA/FSB
kW
0.55 ... 2.2
3TC03-8DD0
mH
0.82
A
45
kW
0.20
IP00
kg
19
Line voltage 3-phase 380 V AC -10% to 480 V AC +10%:
1)
6SL3210-
1PE24-5xL0
FSD
kW
22
Power components on the motor side
0AE18-8CA0
0AE21-8CA0
1.3
0.54
9.0
18.5
0.08
0.08
IP20
IP20
3.9
10.1
6SL3210-
6SL3210-
1PB17-4xL0
1PB21-0xL0
1PB21-4xL0
1PB21-8xL0
6SL3211-
1PB21-0xL0
1PB21-8xL0
6SL3210-
6SL3210-
1PE18-0xL1
1PE21-1xL0
1PE21-4xL0
1PE21-8xL0
6SL3211-
6SL3211-
1PE18-0xL1
1PE21-8xL0
FSA/FSB
FSB/FSC
1.5 ... 3
2.2 ... 7.5
3TC07-5ED0
0.30
90
0.27
IP00
27
6SL3210-
1PE26-0xL0
1PE27-5xL0
1PE28-8xL0
FSD/FSE
30 ... 45
6.1 Motor reactors
0AE23-8CA0
0.26
39.0
0.11
IP20
11.2
6SL3210-
1PE22-7xL0
1PE23-3xL0
1PE23-8xL0
6SL3211-
1PE23-3xL0
FSC/FSD
11 ... 18.5
3TC14-5FD0
0.20
178
0.47
IP00
57
6SL3210-
1PE31-1xL0
FSE
55
127

Advertisement