4.5

Mounting

4.5.1

Mounting instructions

Note
Mounting instructions
• Please refer to the notes for installing Power Modules in Section Safety instructions for
Blocksize Power Modules (PM240-2) (Page 70).
• You must mount the PM240-2 Push Through Power Modules on an unpainted metal
surface in order to comply with EMC requirements.
• To be able to mount PM240-2 Push Through Power Modules, the wall thickness of the
cabinet must be ≤ 3.5 mm.
Note
Installation frame for push through units
An installation frame should be used when push through units are installed in the cabinet.
You can find more information about the installation frame in Section Mounting frame
(Page 222).
This mounting frame includes the necessary seals and frame to ensure compliance with
degree of protection IP54.
If you do not use the mounting frames, you must ensure that the required degree of
protection is complied with using other appropriate measures.
SINAMICS S110
Manual, 07/2015, 6SL3097-4AC10-0BP5
Blocksize Power Modules (PM240-2)
4.5 Mounting
93