Power components on the motor side
6.1 Motor reactors
Risk of burns resulting from high surface temperature of the motor reactor
The motor reactors can become very hot. You can be severely burnt when touching the
surface.
• Mount the motor reactors so that they cannot be touched. If this is not possible, at the
NOTICE
Damage to the motor reactors due to use of non-approved components
If components are used that have not been approved, damage or malfunctions can occur in
the devices or the system itself. There is a risk that the motor reactor will be thermally
damaged.
• Use only motor reactors that have been approved for SINAMICS by Siemens.
NOTICE
Damage to the motor reactor if the maximum output frequency is exceeded
The maximum permissible output frequency when motor reactors are used is 150 Hz. At a
higher output frequency, the motor reactor may be damaged.
• Do not operate the motor reactors above the maximum permissible output frequency of
NOTICE
Damage to the motor reactor if the maximum pulse frequency is exceeded
The maximum permissible pulse frequency when using motor reactors is 4 kHz. At a higher
pulse frequency, the motor reactor may be damaged.
• Do not operate the motor reactors on the Power Module above the maximum
120
CAUTION
dangerous locations, attach an appropriate warning note that is clearly visible and easy
to understand.
150 Hz.
permissible pulse frequency of 4 kHz.
SINAMICS S110
Manual, 07/2015, 6SL3097-4AC10-0BP5