Stand-alone test procedures
...................................................................................................................................................................................................................................
...................................................................................................................................................................................................
12
Disconnect the optical power meter and reconnect the fiber to the receive port of LP1.1.
...................................................................................................................................................................................................
Remove the optical loop from the ODF and install a variable optical attenuator.
13
...................................................................................................................................................................................................
14
Increase the attenuation until the PDH analyzer reports single bit errors.
...................................................................................................................................................................................................
Decrease the attenuation a little until no errors are reported.
15
...................................................................................................................................................................................................
16
Wait for approximately 5 minutes (no errors may occur).
...................................................................................................................................................................................................
Disconnect the fiber from the Line Port "input" at the physical E port and measure the
17
optical output level (refer to
frame test" (p.
...................................................................................................................................................................................................
Verify that the requirements mentioned in the table below are met.
18
Result:
Receiver sensitivity ranges:
Interface
S1.1
S4.1
L1.1
L1.2
L4.1
L4.2
...................................................................................................................................................................................................
19
Repeat test for Line Port 1.2, LP 1.3, LP1.4 , if applicable.
E
N D
O F
...................................................................................................................................................................................................
Cleaning up
The following tasks must be performed to clean up the system:
• Disconnect the PDH analyzer
• Disconnect the optical attenuator
...................................................................................................................................................................................................................................
7-10
Figure 7-2, "Line port connection to optical distribution
7-8)).
Wavelength [nm]
1310
1310
1310
1550
1310
1550
S T E P S
Alcatel-Lucent – Internal
Proprietary – Use pursuant to Company instruction
Line port connection to optical distribution frame test
Receiver sensitivity [dBm]
≤ –28
≤ –28
≤ –34
≤ –34
≤ –28
≤ –28
365-313-103R8.0
Issue 2 July 2009