Load Tftp - Siemens SIMATIC NET Configuration Manual

Industrial wireless lan to ieee 802.11n command line interface
Hide thumbs Also See for SIMATIC NET:
Table of Contents

Advertisement

Configuration
3.2 Load and Save
3.2.3

load tftp

Description
With this command, you load the files from a TFTP server.
Requirement
You are in the User EXEC mode or in the Privileged EXEC mode.
The command prompt is as follows:
cli>
Syntax
Call up the command with the following parameters:
load tftp {ipv4 <ucast_addr> | fqdn-name <FQDN>} [port <tcp port (1-65535)>] file
<filename> filetype <filetype>
The parameters have the following meaning:
Parameter
ipv4
ucast_addr
fqdn-name
FQDN
port
tcp port
file
filename
filetype
filetype
For information on identifiers of addresses and interfaces, refer to the section "Auto-
Hotspot".
For information on the file types , refer to this list.
Result
The file is loaded on the device from the TFTP server.
72
or
cli#
Description
Keyword for an IPv4 address
IPv4 unicast address of the TFTP
server
Keyword for a domain name
Domain name (Fully Qualified Domain
Name) of the TFTP server
Keyword for the port of the server via
which the TFTP connection runs
Number of the port
Keyword for a file name to be assigned -
Name of the file
Keyword for the file type to be loaded
Name of the file type
Range of values / note
Enter a valid unicast IPv4 ad-
dress.
-
Maximum of 100 characters
-
1 ... 65535
Maximum of 100 characters
-
Maximum of 100 characters
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface