No Spanning-Tree Auto-Edge; Spanning-Tree Bdpufilter - Siemens SIMATIC NET Configuration Manual

Industrial wireless lan to ieee 802.11n command line interface
Hide thumbs Also See for SIMATIC NET:
Table of Contents

Advertisement

6.3.4.4

no spanning-tree auto-edge

Description
With this command, you disable automatic discovery of a bridge connected to the interface.
Requirement
You are in the Interface Configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call the command without parameters:
no spanning-tree auto-edge
Result
The automatic discovery of a bridge on the interface is disabled.
Further notes
The automatic discovery of a bridge on the interface is enabled with the
edge
6.3.4.5

spanning-tree bdpufilter

Description
With this command, you configure the BPDU transmit status for a port.
Requirement
You are in the Interface Configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call up the command with the following parameters:
spanning-tree bpdufilter{disable|enable}
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
command.