Network protocols
7.5 SMTP client
Syntax
Call the command without parameters:
no sender mail-address
Result
The e-mail name of the sender is reset.
Further notes
You configure the e-mail name of the sender with the
You display the setting with the
7.5.2.5

smtp-port

Description
With this command, you configure an SMTP port.
Requirement
You are in the EVENTS configuration mode.
The command prompt is as follows:
cli(config-events)#
Syntax
Call up the command with the following parameters:
smtp-port <smtp-port(1-65535)>
The parameter has the following meaning:
Parameter
smtp-port
Result
An SMTP port is configured.
Further notes
You can reset the setting to the default with the
You display the setting with the
358
show events sender email
Description
Value for the SMTP port
show smtp-port
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
sender mail-address
command.
Range of values / note
1 ... 65535
Default: 25
command.
no smtp-port
command.
Configuration Manual, 10/2015, C79000-G8976-C351-05
.