Network structures
6.3 Spanning Tree
The parameters have the following meaning:
Parameter
disable
enable
Result
The BPDU transmit status is configured.
6.3.4.6

spanning-tree bpdu-receive

Description
With this command, you enable or disable the BPDU receive status at the port.
Requirement
You are in the Interface Configuration mode.
The command prompt is as follows:
cli(config-if-$$$)#
Syntax
Call up the command with the following parameters:
spanning-tree bpdu-receive{enabled|disabled}
The parameters have the following meaning:
Parameter
enabled
disabled
Result
The BPDU receive status is enabled or disabled.
Further notes
You can display the status of this function and other information with the
interface
270
Description
The transfer of BPDU packets is disa-
bled for the port
The transfer of BPDU packets is ena-
bled for the port
Description
BPDU packets are received at the port
BPDU packets are ignored at the port
command with the
detail
option.
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 10/2015, C79000-G8976-C351-05
Range of values / note
Default: disabled
-
Range of values / note
Default: enabled
-
show spanning-tree