17
Tables and overviews
17.5
Functions of the TNC 620 and the iTNC 530 compared
Comparison: Differences in Manual Operation,
operation
Function
Capturing the position values
from mechanical probes
Exiting the touch probe functions
menu
Exit the preset table
Multiple editing of tool table
TOOL.T, or pocket table tool_p.tch
Comparison: Differences in Program Run, operation
Function
Arrangement of soft-key rows and
soft keys within the rows
Operating-mode switchover after
program run was interrupted by
switching to the Single Block
mode of operation, and canceled
by INTERNAL STOP
GOTO is used to go to FK
sequences after program run was
interrupted there before switching
the operating mode
Mid-program startup:
Behavior after restoring the
machine status
Completing positioning for mid-
program startup
Switching the screen layout for
mid-program startup
Error messages
560
TNC 620
Actual-position capture by soft key
Only via the END soft key
Only through the BACK/END soft
keys
Soft-key row that was last active
before exiting is active
TNC 620
Arrangement of soft-key rows and soft-keys varies depending on the
active screen layout.
When you return to the Program
Run mode of operation: Error
message Selected block not
addressed. Use mid-program
startup to select the point of
interruption
Error message FK programming:
Undefined starting position
The menu for returning must
be selected with the RESTORE
POSITION soft key
After position has been
reached, positioning mode
must be exited with the
RESTORE POSITION soft key
Only possible, if startup
position has already been
approached
Error messages are still active
after the error has been corrected
and must be acknowledged
separately
iTNC 530
Actual-position capture by hard
key
Via the END soft key or the END
hard key
Through the END hard key at any
time
Permanently defined soft-key row
(soft-key row 1) is displayed
iTNC 530
Switching the operating mode
is allowed, modal information
is saved, program run can be
continued by pressing NC start
GOTO allowed
Menu for returning is selected
automatically
The positioning mode is
automatically exited after the
position has been reached
Possible in all operating states
Error messages are sometimes
acknowledged automatically after
the error has been corrected
TNC 620 | User's Manual
HEIDENHAIN Conversational Programming | 5/2013

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents