Preassigned Q Parameters - HEIDENHAIN TNC 620 User Manual

Conversational programming nc software 340560-04, 340561-04, 340564-04
Hide thumbs Also See for TNC 620:
Table of Contents

Advertisement

8
Programming: Q Parameters
8.12

Preassigned Q parameters

8.12
Preassigned Q parameters
The Q parameters Q100 to Q199 are assigned values by the TNC.
The following types of information are assigned to Q parameters:
Values from the PLC
Tool and spindle data
Data on operating status
Results of measurements from touch probe cycles etc.
The TNC saves the values for the preassigned Q parameters Q108,
Q114 and Q115 to Q117 in the unit of measure used by the active
program.
Do not use preassigned Q parameters (or QS
parameters) between Q100 and Q199 (QS100 and
QS199) as calculation parameters in NC programs.
Otherwise you might receive undesired results.
Values from the PLC: Q100 to Q107
The TNC uses the parameters Q100 to Q107 to transfer values
from the PLC to an NC program.
Active tool radius: Q108
The active value of the tool radius is assigned to Q108. Q108 is
calculated from:
Tool radius R (tool table or TOOL DEF block)
Delta value DR from the tool table
Delta value DR from the TOOL CALL block
The TNC remembers the current tool radius even if
the power is interrupted.
Tool axis: Q109
The value of Q109 depends on the current tool axis:
Tool axis
No tool axis defined
X axis
Y axis
Z axis
U axis
V axis
W axis
298
Parameter value
Q109 = –1
Q109 = 0
Q109 = 1
Q109 = 2
Q109 = 6
Q109 = 7
Q109 = 8
HEIDENHAIN Conversational Programming | 5/2013
TNC 620 | User's Manual

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents