Functions In Touch Probe Cycles - HEIDENHAIN TNC 620 User Manual

Conversational programming nc software 340560-04, 340561-04, 340564-04
Hide thumbs Also See for TNC 620:
Table of Contents

Advertisement

13
Manual operation and setup
13.5 Using 3-D touch probes (Touch Probe Function software option)

Functions in touch probe cycles

Soft keys that are used to select the probing direction or a probing
routine are displayed in the manual touch probe cycles. The soft
keys displayed vary depending on the respective cycle:
Soft key
Function
Select the probing direction
Capture the actual position
Probe hole (inside circle) automatically
Probe stud (outside circle) automatically
Automatic probing routine for holes and studs
If you use a function for probing a circle
automatically, the TNC automatically positions
the touch probe to the respective touch points.
Ensure that the positions can be approached without
collision.
If you use a probing routine for probing a hole or a stud
automatically, the TNC opens a form with the required input fields.
Input fields in the Measure stud and Measure hole forms
Input field
Stud diameter? or Hole
diameter?
Safety clearance?
Incr. clearance height?
Starting angle?
Number of touch
points?
Angular length?
428
Function
Diameter of probe contact (optional
for holes)
Distance to the probe contact in
the plane
Positioning of touch probe in
spindle axis direction (starting from
the current position)
Angle for the first probing
operation (0° = Positive direction of
principal axis, i.e. in X+ for spindle
axis Z). All other probe angles
result from the number of touch
points.
Number of probing operations (3 to
8)
Probing a full circle (360°)
or a circle segment (angular
length<360°)
TNC 620 | User's Manual
HEIDENHAIN Conversational Programming | 5/2013

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents