Checking And Changing Q Parameters - HEIDENHAIN TNC 620 User Manual

Conversational programming nc software 340560-04, 340561-04, 340564-04
Hide thumbs Also See for TNC 620:
Table of Contents

Advertisement

8
Programming: Q Parameters
8.7

Checking and changing Q parameters

8.7
Checking and changing Q parameters
Procedure
You can check Q parameters in all operating modes (when writing,
testing and running programs) and also edit them.
If you are in a program run, interrupt it if required (for example,
by pressing the machine STOP button and the INTERNAL STOP
soft key). If you are in a test run, interrupt it.
Call Q-parameter functions: Press the Q INFO soft
key or the Q key.
The TNC lists all parameters and their current
values. Use the arrow keys or the GOTO key to
select the desired parameter.
If you would like to change the value, press the
EDIT CURRENT FIELD soft key, enter the new
value, and confirm with the ENT key.
To leave the value unchanged, press the PRESENT
VALUE soft key or end the dialog with the END
key.
The parameters used by the TNC internally or in
cycles are provided with comments.
If you want to check or edit local, global or string
parameters, press the SHOW PARAMETERS Q QL
QR QS soft key. The TNC then displays the specific
parameter type. The functions previously described
also apply.
250
TNC 620 | User's Manual
HEIDENHAIN Conversational Programming | 5/2013