14. Service call message
14.3.7
0043: Cooling Fan Motor/1's failure to turn
Cooling Fan Motor/1 (M12)
Step
Check the connector of motor for proper
1
connection and correct as necessary.
Check the fan for possible overload and
2
correct as necessary.
M12 operation check
3
4
Change PWB-M
14.3.8
0046: Fusing Cooling Fan Motor /1's failure to turn
Fusing Cooling Fan Motor/1 (M11)
Step
Check the connector of motor for proper
1
connection and correct as necessary.
Check the fan for possible overload and
2
correct as necessary.
M11 operation check
3
4
Change PWB-M
14.3.9
0048: Fusing Cooling Fan Motor /2's failure to turn
Fusing Cooling Fan Motor/2 (M13)
Step
Check the connector of motor for proper
1
connection and correct as necessary.
Check the fan for possible overload and
2
correct as necessary.
M13 operation check
3
4
Change PWB-M