Scanner Drive Mechanism

(1)
Scanner Drive Mechanism
• The Scanner Motor drives the Scanner Assy through the Timing Belt.
Scanner Motor (M4)
Timing Belt
8-4.

Scanner Motor Drive Control

• The speed at which the Scanner moves (for scan and return motion) is controlled by
varying the period of the motor drive pulse that is timed with the reference clock.
Period
• The number of motor drive pulses as determined according to the paper size and zoom
ratio controls the amount of movement of the Scanner.
Electrical Component
M4
speed
speed
Control Signal
PWB-P P105P-1~4
M-17
Scanner Assy
High
Low
ON
OFF
WIRING DIAGRAM
Pulse output
4980M002AA
B~C-7