Field Service Ver. 1.0 May 2006

16. Image quality problem

16.1 How to read Element date

• Utilize the Element data which is output by selecting [DIAGNOSIS MENU] → [PRINT
MENU] → [ELEMENT PAGE] on the SERVICE MENU to specify the cause for the trou-
ble.
• For details on Element data for each item, see "Adjustment/Setting."
See P.160
CONTROLLER F/W :
ENGINE F/W :
BOOT F/W :
SERIAL NUMBER :
ENGINE OEM CODE :
Element Data
INSIDE HUMIDITY
ABSOLUTE HUMIDITY
INSIDE TEMPERATURE
SENSOR INFORMATION1
SENSOR INFORMATION2
SENSOR INFORMATION3
SENSOR INFORMATION4
SENSOR INFORMATION5
SENSOR INFORMATION6
FUSER HEATER1 TEMPERATURE
FUSER HEATER2 TEMPERATURE
IDC REGIST SENSOR1
IDC REGIST SENSOR2
TCR SENSOR C
TCR SENSOR M
TCR SENSOR Y
TCR SENSOR K
VG VOLT C
VG VOLT M
VG VOLT Y
VG VOLT K
VB VOLT C
VB VOLT M
VB VOLT Y
VB VOLT K
IDC BASE REFLECTION1
IDC BASE REFLECTION2
Engine Element Data Information
Product Name : magicolor7450
Printer Name : MC7450-C438AE
403930G0080100 (US)
DATE :
403950G0010001 (US)
TIME :
403999G0010000
321700001
0x10
44%
THICKSTOCK VG VOLT C
3
16g/cm
THICKSTOCK VG VOLT M
33 C
THICKSTOCK VG VOLT Y
0x1555
THICKSTOCK VG VOLT K
0x1c23
THICKSTOCK VB VOLT C
0x0c00
THICKSTOCK VB VOLT M
0x0100
THICKSTOCK VB VOLT Y
0x03a0
THICKSTOCK VB VOLT K
0x000d
MONOCHROME VG VOLT C
171 C
MONOCHROME VG VOLT M
MONOCHROME VG VOLT Y
171 C
4.62V
MONOCHROME VG VOLT K
MONOCHROME VB VOLT C
4.14V
8.31%
MONOCHROME VB VOLT M
MONOCHROME VB VOLT Y
8.54%
8.57%
MONOCHROME VB VOLT K
8.20%
TRANS CURRENT1
545V
TRANS CURRENT2
REGIST SKEW C
505V
455V
REGIST SKEW M
403V
REGIST SKEW Y
436V
417V
363V
307V
43
41
16. Image quality problem
03.14.2006
00:00
544V
504V
455V
403V
436V
417V
363V
307V
403V
403V
403V
403V
307V
307V
307V
307V
+783V
+937V
-4
+2