3 SPECIFICATION
Master station
Remote output (RY)
Address
160
RY F to RY 0
H
For station No.1
161
RY 1F to RY 10
H
162
RY 2F to RY 20
H
For station No.2
163
RY 3F to RY 30
H
164
RY 4F to RY 40
H
For station No.3
165
RY 5F to RY 50
H
166
RY 6F to RY 60
H
For station No.4
167
RY 7D to RY 70
H
168
RY 8F to RY 80
H
For station No.5
169
RY 9F to RY 90
H
16A
RY AF to RY A0
H
For station No.6
16B
RY BF to RY B0
H
16C
RY CF to RY C0
H
For station No.7
16D
RY DF to RY D0
H
16E
RY EF to RY E0
H
For station No.8
16F
RY FD to RY F0
H
170
RY10F to RY100
H
For station No.9
171
RY11F to RY110
H
172
H
to
1DB
H
1DC
RY7CF to RY7C0
H
For station No.63
1DD
RY7DF to RY7D0
H
1DE
RY7EF to RY7E0
H
For station No.64
RY7FF to RY7F0
1DF
H
Master station's buffer memory and station number correspondence table
Station
Buffer memory
Station
number
address
number
1
160
to 161
H
H
2
162
to 163
H
H
3
164
to 165
H
H
4
166
to 167
H
H
5
168
to 169
H
H
6
16A
to 16B
H
H
7
16C
to 16D
H
H
8
16E
to 16F
H
H
9
170
to 171
H
H
10
172
to 173
H
H
11
174
to 175
H
H
12
176
to 177
H
H
13
178
to 179
H
H
(b) Master station
station
Master station
1
Output status to remote I/O station, remote device station (RY) and all
local stations (RX) are stored.
Two words are used per station.
(station No.1: occupies 1 station)
to
Buffer memory
Station
address
number
14
17A
to 17B
27
H
H
15
17C
to 17D
28
H
H
16
17E
to 17F
29
H
H
17
180
to 181
30
H
H
18
182
to 183
31
H
H
19
184
to 185
32
H
H
20
186
to 187
33
H
H
21
188
to 189
34
H
H
22
18A
to 18B
35
H
H
23
18C
to 18D
36
H
H
24
18E
to 18F
37
H
H
25
190
to 191
38
H
H
26
192
to 193
39
H
H
remote I/O station/remote device station/local
Remote I/O station
Y0F to Y00
Y1F to Y10
Buffer memory
Station
Buffer memory
address
number
194
to 195
40
1AE
H
H
196
to 197
41
1B0
H
H
198
to 199
42
1B2
H
H
19A
to 19B
43
1B4
H
H
19C
to 19D
44
1B6
H
H
19E
to 19F
45
1B8
H
H
1A0
to 1A1
46
1BA
H
H
1A2
to 1A3
47
1BC
H
H
1A4
to 1A5
48
1BE
H
H
1A6
to 1A7
49
1C0
H
H
1A8
to 1A9
50
1C2
H
H
1AA
to 1AB
51
1C4
H
H
1AC
to 1AD
52
1C6
H
H
3 - 26
MELSEC-A
Remote device station
(station No.2: occupies 2 stations)
Remote output (RY)
RY0F to RY00
RY1F to RY10
Station
Buffer memory
address
number
address
to 1AF
53
1C8
to 1C9
H
H
H
to 1B1
54
1CA
to 1CB
H
H
H
to 1B3
55
1CC
to 1CD
H
H
H
to 1B5
56
1CE
to 1CF
H
H
H
to 1B7
57
1D0
to 1D1
H
H
H
to 1B9
58
1D2
to 1D3
H
H
H
to 1BB
59
1D4
to 1D5
H
H
H
to 1BD
60
1D6
to 1D7
H
H
H
to 1BF
61
1D8
to 1D9
H
H
H
to 1C1
62
1DA
to 1DB
H
H
H
to 1C3
63
1DC
to 1DD
H
H
H
to 1C5
64
1DE
to 1DF
H
H
H
to 1C7
H
H
H
H
H
H
H
H
H
H
H
H
H
H