Mitsubishi A1SJ61BT11 User Manual page 178

Control & communication link system master/local module, melsec a
Table of Contents

Advertisement

8 PROGRAMMING
Number
Name
SW0094
(694
)
H
SW0095
(695
)
Transient transmission
H
SW0096
error status 1
(696
)
H
SW0097
(697
)
H
SW0098
(698
)
H
SW0099
(699
)
Station number overlap
H
SW009A
status
4
(69A
)
H
SW009B
(69B
)
H
SW009C
(69C
)
H
SW009D
(69D
)
Loading/parameter
H
SW009E
consistency status
(69E
)
H
SW009F
(69F
)
H
SW00B4
(6B4
)
H
SW00B5
(6B5
)
H
Line test 1 result
SW00B6
(6B6
)
H
SW00B7
(6B7
)
H
SW00B8
Line test 2 result
(6B8H)
2
E
PROM registration
SW00B9
(6B9H)
status
SW00BA 5
2
E
PROM erasure result
(6BA
)
H
Checks the number of
times when parameters
SW00BB 5
can be registered to
(6BB
)
H
2
E
PROM.
: It is the link special relay which had been added by function version B or later.
1 : Turns on only the bit for the head station number.
3 : Turns on the bit for the number of occupied stations.
4 : Turns on only the bit for the head station number.And check is performed only when the link is started up, and stored.
5 : Link special register added to the software version E (manufactured in Aug., 2001) or later of the A1SJ61BT11.
Table 8.2 Link special register list (continued)
Stores the transient transmission error occurrence status for each
station.
0: Normal
1: Transient transmission error occurrence
b15
b14
SW0094
16
SW0095
32
SW0096
48
SW0097
64
1 to 64 in the table indicates station numbers.
The overlapping status is stored when each module's first station
number dose not overlap.
0: Normal
1: Station number overlaps (only for the first station number)
b15
b14
SW0098
16
SW0099
32
SW009A
48
SW009B
64
1 to 64 in the table indicates station numbers.
The consistency status with the parameters are stored.
0: Normal
1: Consistency error
b15
SW009C
16
4
SW009D
32
SW009E
48
SW009F
64
1 to 64 in the table indicates station numbers.
Line test 1 test results are stored.
0: Normal
1: Error
b15
b14
3
SW00B4
16
SW00B5
32
SW00B6
48
SW00B7
64
1 to 64 in the table indicates station numbers.
Stores the line test 2 results.
0
: Normal
Other than 0 : Stores error code (Refer to Section 13.3.)
2
E
PROM parameter registration status is stored.
0
: Normal
Other than 0 : Stores error code (Refer to Section 13.3.)
2
The result of E
PROM erasure request (YnD) is stored.
0
: Normal
Other than 0 : Stores the error code.
The number of times when parameters can be registered to
2
E
PROM is stored.
Decremented when the parameter registration request to E
(YnA) is given.
Description
b13
b12
to
b3
15
14
13
to
4
31
30
29
to
20
47
46
45
to
36
63
62
61
to
52
b13
b12
to
b3
15
14
13
to
4
31
30
29
to
20
47
46
45
to
36
63
62
61
to
52
b14
b13
b12
to
b3
15
14
13
to
4
31
30
29
to
20
47
46
45
to
36
63
62
61
to
52
b13
b12
to
b3
15
14
13
to
4
31
30
29
to
20
47
46
45
to
36
63
62
61
to
52
8 - 20
MELSEC-A
Availability
(
: available,
: not available )
Online
Master
station
b2
b1
b0
3
2
1
19
18
17
35
34
33
51
50
49
b2
b1
b0
3
2
1
19
18
17
35
34
33
49
51
50
b2
b1
b0
3
2
1
19
18
17
35
34
33
49
51
50
b2
b1
b0
3
2
1
19
18
17
35
34
33
49
51
50
2
PROM
Offline
Local
station

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aj61bt11A1sj61qbt11Aj61qbt11

Table of Contents