15 FUNCTIONS (FUNCTION VERSION B OR LATER)
Table 15.9 List of link special resisters relating to temporary error invalid station specifying function
Number
Name
SW0003
Multiple temporary error
(603
)
invalid station specification
H
SW0004
(604
)
H
SW005
(605
)
H
Temporary error invalid
station specification
SW006
(606
)
H
SW007
(607
)
H
SW0049
Temporary error invalid
(649
)
station request result
H
Temporary error invalid
SW004B
station canceling request
(64B
)
H
result
SW007C
(67C
)
H
SW007D
(67D
)
Temporary error invalid
H
station specifying status
SW007E
1
(67E
)
H
SW007F
(67F
)
H
1 Turns on only the bit for the head station number.
POINT
(1) If both a temporary error invalid station request and a temporary error invalid station
canceling request are made, the temporary error invalid station canceling request will be
given a priority.
(2) For a station that occupies multiple stations, only the head station number becomes valid.
(2) Special link registers (SW)
The link special resisters (SW) relating to the temporary error invalid station
specifying function are as follows. The figures in parentheses in the number
column indicate buffer memory address.
Selects whether to specify multiple temporary error invalid stations.
00
: Specifies multiple stations as indicated in SW0004 to
SW0007.
01 to 64 : Specifies a single station from 1 to 64.
Specifies the station number used as the temporary invalid station.
Specifies the temporary error invalid station.
0: Not specified as a temporary error invalid station.
1: Specified as a temporary error invalid station.
b15
b14
SW0004
16
1
SW0005
32
SW0006
48
SW0007
64
Stores the results of execution of the temporary error invalid station
request instruction by SB0004.
0
: Normal
Other than 0 : Store error code (See Section 13.3)
Stores the results of execution of the temporary error invalid station
canceling request instruction by SB0005.
0
: Normal
Other than 0 : Store error code (See Section 13.3)
Stores the temporary error invalid station specifying status.
0: Other than temporary error invalid station
1: Temporary error invalid station
b15
b14
SW007C
16
SW007D
32
48
SW007E
SW007F
64
Description
b13
b12
to
b3
15
14
13
to
4
31
30
29
to
20
47
46
45
to
36
63
62
61
to
52
1 to 64 in the table indicate station numbers.
b13
b12
to
b3
15
14
13
to
4
31
29
30
to
20
47
46
45
to
36
63
62
61
to
52
1 to 64 in the table indicate station numbers.
15 - 15
MELSEC-A
Availability
(
: available,
: not available)
Master station Local station
b2
b1
b0
3
2
1
19
18
17
35
34
33
51
50
49
b2
b1
b0
3
2
1
19
18
17
35
34
33
51
50
49

Hide quick links: