RIO file
Relay data Interchange format by Omicron.
RSxxx-interface
Serial interfaces RS232, RS422/485
SCADA Interface
Rear serial interface on the devices for connecting to a control system via IEC or
PROFIBUS.
Service port
Rear serial interface on the devices for connecting DIGSI (for example, via modem).
Setting parameters
General term for all adjustments made to the device. Parameterization jobs are exe-
cuted by means of DIGSI or, in some cases, directly on the device.
→ Single point indication
SI
→ Single-point indication fleeting → Transient information, → Single point indication
SI_F
Modularly structured station control system, based on the substation controller →
SICAM SAS
SICAM SC and the SICAM WinCC operator control and monitoring system.
SICAM SC
Substation Controller. Modularly structured substation control system, based on the
SIMATIC M7 automation system.
SICAM WinCC
The SICAM WinCC operator control and monitoring system displays the state of your
network graphically, visualizes alarms, interrupts and indications, archives the network
data, offers the possibility of intervening manually in the process and manages the
system rights of the individual employee.
Single command
Single commands are process outputs which indicate 2 process states (for example,
ON/OFF) at one output.
Single point indica-
Single indications are items of process information which indicate 2 process states (for
tion
example, ON/OFF) at one output.
SIPROTEC
The registered trademark SIPROTEC is used for devices implemented on system
base V4.
SIPROTEC 4 device
This object type represents a real SIPROTEC 4 device with all the setting values and
process data it contains.
SIPROTEC 4
This object type represents a variant of an object of type SIPROTEC 4 device. The
variant
device data of this variant may well differ from the device data of the source object.
However, all variants derived from the source object have the same VD address as
the source object. For this reason they always correspond to the same real SIPRO-
TEC 4 device as the source object. Objects of type SIPROTEC 4 variant have a variety
of uses, such as documenting different operating states when entering parameter set-
tings of a SIPROTEC 4 device.