Graco PGM Instructions - Parts Manual page 41

Precision gear metering
Hide thumbs Also See for PGM:
Table of Contents

Advertisement

PGM-6 Pump Disassembly
1. Prepare Gear Meter Assembly for Repair,
page 35.
2. Refer to Gear Pump Maintenance Guide on
page 47 for special notes regarding gear pump
repair.
3. Remove four pump block shoulder bolts (1102).
Pump section should be fully supported to prevent
damage being dropped. It is recommended that the
gear meter assembly be located on a work bench for
service.
4. Remove drive assembly. See F
Thicker materials may require heating prior to disas-
sembly. Do not expose the pump to thermal shock.
Raise temperature at a maximum rate of 180°F
(100°C) per hour. Do not exceed 400°F (204°C).
Exceeding this temperature could promote leakage in
the pump. Gradually cool the pump to room tempera-
ture.
5. Remove seal retainer fasteners (1614) and seal
retainers (1611).
6. Remove pump dowel pins (1610) using an arbor
press.
Do not use a hammer to remove dowel pins as this
will damage the pump.
7. Remove the pump plate screws (1613).
8. Separate the pump front plate (1601), gear case
(1602) and back plate (1603).
3A5185B
NOTICE
. 23.
IG
NOTICE
NOTICE
NOTE: Notches on the pump plates can be used to
separate the plates.
9. To remove the drive shaft (1605) from the bottom
plate (1603) press the shaft and gear from the bot-
tom pump plate towards the coupling end.
10. To remove the drive gear (1607) from the drive shaft
(1605), support the drive gear at the lower end to
allow the shaft to be pressed through the gear from
the top or coupling end. Make sure to leave clear-
ance for the drive key.
11. The stud (1606) for the driven gear (1608) is press
fit into the back plate (1603) and need not be
removed if not worn.
The PGM pump design relies on a lap fit between
components for performance and sealing. Be careful
not to drop the gears (1607, 1608) or damage the
mating surfaces of the pump plates (1601, 1603) and
gear case (1602). To prevent damage, do not use pli-
ers or screwdrivers to remove the gears.
12. Clean all components thoroughly before reassem-
bly. The use of an ultrasonic cleaner is recom-
mended.
NOTICE
Repair
41

Advertisement

Table of Contents
loading

Table of Contents