Configure Control Settings

Set the controls for the dispense source, how dispense
commands are sent, and auto mode settings.
1. From the Home screen, select the Setup icon
.
NOTE: The Setup screens are password protected.
Enter password "PGM17"to access the following
screens.
F
. 11
IG
2. Select Display or Remote from the Command Value
Source Options.
3. If Command Value Source is set to Remote,
enter the Remote Max Flow (cc/min) for the 10 VDC
command source.
4. Select Enable or Disable for Run Mode Bead Adjust
Options. Default is Disable.
5. Select Display or Remote for Job End Mode
Options.
6. If Job End Mode is set to Display, press Job End
Delay Display field and enter desired delay time in
seconds.
3A5185B

Configure Mode Settings

Set the dispense mode (bead or shot). The bead scale
and pre-charge are also adjustable from the Mode Set-
tings screen.
NOTE: See Appendix A - User Interface Display on
page 82 for a description of each feature.
1. With the system in setup mode, press
igate to the Mode Settings screen.
F
. 12
IG
2. Select Bead or Shot for the Dispense Mode.
3. If Command Value Source is set to Display, enter
the flow rate in cc/min in the Fixed Command Flow
Rate. See Configure Control Settings for instruc-
tions to set the Command Value Source value.
4. If Shot Time is displayed, enter the Shot Time in
Seconds.
NOTE: Shot Time is only displayed if Dispense
Mode is set to Shot.
System Setup
to nav-
19