Graco PGM Instructions - Parts Manual page 33

Precision gear metering
Hide thumbs Also See for PGM:
Table of Contents

Advertisement

Error
No.
Error Name
9
Outlet Max Pressure
Fault - Relieve Pres-
sure and Cycle Power
10
Drive Torque Devia-
tion
11
Drive Torque Error
12
Drive Peak Torque
Error - Drive disabled,
Cycle Power
13
Pre-Charge Timeout
14
High Pressure Inter-
lock OFF
15
Dispense Valve Open
(Auto Default)
16
Calibration is enabled
complete calibration
procedure
17
Drive Fault, Cycle
Power
18
Calibration out of
range
3A5185B
Error Description
Outlet material pres-
sure exceeds max
rated pressure
Motor exceeds con-
tinuous rated torque
Motor exceeds con-
tinuous rated torque
Motor exceeds peek
torque rating
Pre-Charge Pressure
was not reached
after dispense
Pressure limit is
bypassed
Dispense valve is
open
Calibration mode
enabled
Motor drive is dis-
abled
Calibration values
are out of range or
flow rate is too low
for current K factor
Error
Type
Cause
Alarm
Dispense valve
not opening. Flow
rate too high.
Material not at
temperature.
Deviation
Flow rate too high.
Dispense Valve
not opening.
Material not at
temperature.
Alarm
Flow rate too high.
Dispense Valve
not opening.
Material not at
temperature.
Alarm
Flow rate too high.
Dispense Valve
not opening.
Material not at
temperature.
Advisory
Pre-Charge value
not set correctly.
Advisory
Pressure sensors
are disabled.
Advisory
Dispense valve
open button has
been selected.
Advisory
Calibration
enabled selected
from the calibrate
screen.
Alarm
Various condi-
tions.
Advisory
Improper calibra-
tion, flow rate too
low, or pump
wear.
Errors
Solution
Perform pressure
relief procedure;
Cycle Power; Verify
Dispense valve func-
tion; Perform weight
check verification;
Reduce flow rate.
Lower flow rate;
reduce outlet pres-
sure drop; Verify
material temperature.
Lower flow rate;
reduce outlet pres-
sure drop; Verify
material temperature.
Cycle Power Lower
flow rate; reduce out-
let pressure drop;
Verify material tem-
perature.
Set Pre-Charge to
zero. Monitor outlet
pressure; Adjust
Pre-Charge pressure.
Contact Graco cus-
tomer service.
From the Mainte-
nance screen select
Dispense valve Auto.
Complete calibration
procedure.
Cycle Power verify
motor torque during
dispense.
Perform calibration
procedure.
33