Digital Outputs

The three digital outputs are Dispenser Ready, Fault
Present and In Cycle. These outputs perform high-side
switching of 24 VDC and require a 24 VDC current sink-
ing input at the automation controller. See F
automation controller uses 24 VDC relay coils to receive
I/O signals, the signals should be connected as shown
in F
. 42.
IG
If the automation controller inputs are current sourcing
or use a voltage other than 24 VDC, relays with 24 VDC
coils must be used as shown in F
PGM Control
Pins 10, 11, 12
6
DC Common
Output Circuit
F
. 42
IG
3A5185B
. 42. If the
IG
. 42.
IG
Automation
Load
(750 mA max)