Install Gear Meter Assembly - Graco PGM Instructions - Parts Manual

Precision gear metering
Hide thumbs Also See for PGM:
Table of Contents

Advertisement

Installation
Electrical Connections
Follow these precautions when grounding, connect-
ing cables, connecting to a power source or making
other electrical connections.
To reduce the risk of fire, explosion, or electric
shock:
The control center must be electrically connected
to a true earth ground; the ground in the electrical
system may not be sufficient.
A qualified electrician must complete all ground-
ing and wiring connections.
For wiring, refer to F
Refer to your local code for the requirements for a
"true earth ground" in your area.
If power and grounding connections are not done prop-
erly, the equipment will be damaged and the warranty
voided.
L1
F
. 6: 240 Vac Wiring
IG
14
. 6.
IG
NOTICE
L2
Ground

Install Gear Meter Assembly

To install the PGM metering assembly:
Mount the gear meter assembly.
Ground gear meter assembly.
Connect the gear meter assembly to the control cen-
ter.
Connect fluid lines and cables.
Mount
Before Mounting Assembly
See component manuals for specific information on
component requirements. Information presented
here pertains to the PGM gear meter assembly only.
Have all system and subassembly documentation
available during installation.
Be sure all accessories are adequately sized and
pressure-rated to meet the system's requirements.
Use only the Graco PGM gear meter assembly with
the Graco PGM control center.
Mount Assembly
1. Select a location for the gear meter assembly. Keep
the following in mind:
Allow sufficient space for installing the equip-
ment.
Make sure all fluid lines, cables and hoses eas-
ily reach the components to which they will be
connected.
Make sure the gear meter assembly allows the
automation unit to move freely along all axis.
Make sure the gear meter assembly provides
easy access for servicing its components.