Graco 244075 Instructions-Parts List Manual

Graco 244075 Instructions-Parts List Manual

In-line electronic lubricant meter for use with petroleum-based lubricants only
Hide thumbs Also See for 244075:

Advertisement

Parts
Instructions - Parts List
In-Line Electronic Lubricant Meter
1500 psi (10.3 MPa, 103bar) Maximum Working Pressure
244075
244076
*Meter is factory-set in quarts.

Table of Contents

GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440-1441
Copyright 2002, Graco Inc. is registered to I.S. EN ISO 9001
FOR USE WITH PETROLEUM-BASED LUBRICANTS ONLY
Measures in gallons, quarts and pints*
Measures in liters
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
2
5
6
8
9
10
11
11
12
12
307965T
02171

Advertisement

Table of Contents
loading

Summary of Contents for Graco 244075

  • Page 1: Table Of Contents

    ......GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440-1441 Copyright 2002, Graco Inc. is registered to I.S. EN ISO 9001...
  • Page 2: Warnings

    D This equipment is for professional use only. D Read all instruction manuals, tags, and labels before you operate the equipment. D Use the equipment only for its intended purpose. If you are not sure, call your Graco representa- tive.
  • Page 3 WARNING INJECTION HAZARD Spray from the dispensing valve, leaks, or ruptured components can inject fluid into your body and cause extremely serious injury, including the need for amputation. Fluid splashed in the eyes or on the skin can also cause serious injury. D Fluid injected into the skin may look like just a cut, but it is a serious injury.
  • Page 4 Notes 307965 - 4 -...
  • Page 5: Installation

    These meters must be installed in-line as part of a dispense system as shown in Fig. 1; however, the typical instal- lation shown is only a guide for selecting and installing an in-line meter. It is not an actual system design. Contact your Graco representative for assistance in designing a system to suit your needs. In-line meter...
  • Page 6: Operation

    Operation To Change the Measurement Units CAUTION (gallon/quart/pint meter only) Never operate the meter with the black plastic The meter is factory-set to dispense in quarts. To cover removed. The cover protects the meter from change the measurement units, press and hold the damage due to impact.
  • Page 7 (gallon/quart/pint meter only) Set the meter to dispense in pints or quarts when dispensing 1 gallon or less. Always press the RESET key pad to clear the meter before a new dispense cycle. GRACO TOTAL RESET Press RESET to clear DIGITAL DISPLAY Fig.
  • Page 8: Troubleshooting

    Troubleshooting Pressure Relief Procedure WARNING 1. Turn off the power supply to the pump. PRESSURIZED EQUIPMENT HAZARD The equipment stays pressurized until pressure is manually relieved. To 2. Trigger the valve into a waste container to relieve reduce the risk of serious injury from pressure.
  • Page 9: Service

    Service 1. Relieve the pressure. CAUTION To avoid damaging the electronic components of WARNING the control: D Always use the personal grounding strap To reduce the risk of serious injury, when you are instructed to relieve pressure, always follow the provided with a replacement metering unit Pressure Relief Procedure on page 8.
  • Page 10: Parts

    112093 SCREW WARNING Model 244076, Liter Includes replaceable items 1, 3, 4, and 6. Use only genuine Graco replacement parts. This could result in a failure, which could cause serious bodily injury and/or substantial property damage. Part No. Description 191782...
  • Page 11: Accessories

    Accessories Strainer 223179 Shutoff valve 108458 Install between the shutoff valve and the meter. Install upstream from the meter. Shuts off fluid supply Removes particles from the lubricant. 40-mesh. 1/2” from the pump. 1/2–14 npt(f) both ends. npt (m x f). 02177 Technical Data Flow range *...
  • Page 12: Warranty

    Graco distributor to the original purchaser for use. As purchaser’s sole remedy for breach of this warranty, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment proven defective, with the exception of defects in the electronic meter control, including the battery, which will be repaired or replaced for twenty-four months from the date of sale.

This manual is also suitable for:

244076