Operation; Startup; Load Material - Graco PGM Instructions - Parts Manual

Precision gear metering
Hide thumbs Also See for PGM:
Table of Contents

Advertisement

Operation

Operation

Startup

Initial Startup
1. Ensure the PGM control enclosure and all of the
proper connections to and from the control enclo-
sure have been made. Ensure fittings are tight.
2. Read and understand the Operation and User
Interface sections of this manual along with the
related manuals.
3. Continue startup with Step 2 in Standard Startup.
Standard Startup
1. Carefully inspect the entire system for signs of leak-
age or wear. Replace or repair any worn or leaking
components before operating the system.
2. Press the Stop button on the control enclosure.
3. Turn on air and electrical power to the system.
4. Turn on the main power to supply power to the
PGM.
5. Check Interface Signals: If this is a new installa-
tion, power on each system input and verify that
each input is being received. See Appendix B - I/O
on page 98.
6. For heated systems, open the dispense valve over a
waste container while the system is heating up. This
will prevent a pressure build-up caused by fluids or
gases expanding from the heat.
7. Turn on the material supply system.
22

Load Material

Before using the system, material must be loaded into
the supply system.
1. If this is a new installation, follow the Initial Startup
procedure. Otherwise, follow the Standard Startup
procedure.
2. Turn on the fluid supply pressure to the fluid inlet
block for the PGM.
3. Place the dispense valve over a waste container.
4. Navigate to the Maintenance screen. See Screen
Navigation Diagram on page 82 in the Appendix
A - User Interface Display section.
5. Select Manual Control Mode
6. Enter the minimum flow rate to prime the system.
See the following table.
Pump Size
cc / revolution
6
20
7. Press and hold the manual start button
Dispense fluid until clean, air-free fluid flows from
the dispense valve.
NOTE: The manual purge button on the user-inter-
face panel can be used to prime the system.
8. If desired, press
screen.
Min Flow Rate
cc / minute
12
40
to navigate to the Home
3A5185B
.
.

Advertisement

Table of Contents
loading

Table of Contents