Installation
Electrical Connections
Follow these precautions when grounding, connect-
ing cables, connecting to a power source or making
other electrical connections.
To reduce the risk of fire, explosion, or electric
shock:
•
The control center must be electrically connected
to a true earth ground; the ground in the electrical
system may not be sufficient.
•
A qualified electrician must complete all ground-
ing and wiring connections.
•
For wiring, refer to F
Refer to your local code for the requirements for a
"true earth ground" in your area.
If power and grounding connections are not done prop-
erly, the equipment will be damaged and the warranty
voided.
L1
F
. 6: 240 Vac Wiring
IG
14
. 6.
IG
NOTICE
L2
Ground
Install Gear Meter Assembly
To install the PGM metering assembly:
•
Mount the gear meter assembly.
•
Ground gear meter assembly.
•
Connect the gear meter assembly to the control cen-
ter.
•
Connect fluid lines and cables.
Mount
Before Mounting Assembly
•
See component manuals for specific information on
component requirements. Information presented
here pertains to the PGM gear meter assembly only.
•
Have all system and subassembly documentation
available during installation.
•
Be sure all accessories are adequately sized and
pressure-rated to meet the system's requirements.
•
Use only the Graco PGM gear meter assembly with
the Graco PGM control center.
Mount Assembly
1. Select a location for the gear meter assembly. Keep
the following in mind:
•
Allow sufficient space for installing the equip-
ment.
•
Make sure all fluid lines, cables and hoses eas-
ily reach the components to which they will be
connected.
•
Make sure the gear meter assembly allows the
automation unit to move freely along all axis.
•
Make sure the gear meter assembly provides
easy access for servicing its components.
3A5185B